Journal of Theoretical
and Applied Mechanics

0, 0, pp. , Warsaw 0

COMPARATIVE ANALYSIS OF RCM MECHANISMS BASED ON PARALLELOGRAM USED IN SURGICAL ROBOTS FOR LAPAROSCOPIC MINIMALLY INVASIVE SURGERY

Roman Trochimczuk
This article presents the results of comparative analysis of the kinematics and dynamics of five varieties of the parallelogram-based RCM mechanism applied in real-life designs of surgical robots. Analyses were conducted using ANSYS Workbench v. 16.2. Obtained results will allow for formulation of guidelines concerning conscious selection of the form of RCM mechanism and assessment of its usefulness from the perspective of application in new solutions of laparoscopic surgical robots.
Keywords: RCM mechanism, parallelogram, surgical robots, MIS, FEM simulation

References


Ansys Inc., 2013, Ansys Mechanical APDL Contact Technology Guide, Release 15.0

Bai G., Li D., Wei S., Liao Q., 2014, Kinematics and synthesis of a type of mechanisms with multiple remote centers of motion. Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science, 228(18), 3430-3440

Chen Z., Li J., Zhang G., Wang S., 2015, A class of 1 DOF planar RCM mechanism based on motion-reproduce method. In Robotics and Biomimetics (ROBIO), 2015 IEEE International Conference on , 1433-1438

Chng C.B., Duan B., Chui C.K., 2016, Modeling and simulation of a Remote Center of Motion mechanism. In Region 10 Conference(TENCON), 2016 IEEE, 1755-1758

Choi H., Kim H.J., Lim Y.A., Kwak H.S., Jang J.W., Won J., 2013, Conically shaped remote center-of-motion mechanism for single-incision surgery. In Intelligent Robots and Systems (IROS), 2013 IEEE/RSJ International Conference on, 3604-3609

Craig J.J., 2005, Introduction to Robotics. Mechanics and control, Upper Saddle River, Pearson/Prentice Hall, NJ, USA

Fu Y., Niu G., Pan B., Li K., Wang S., 2013, Design and optimization of remote center motion mechanism of minimally Invasive surgical robotics. In Robotics and Biomimetics (ROBIO), 2013 IEEE International Conference on, 774-779

Gijbels A., Reynaerts D., Vander Poorten E.B., 2014, Design of 4-DOF Parallelogram-based RCM Mechanisms with a Translational DOF Implemented Distal from the End-effector. In Advances on Theory and Practice of Robots and Manipulators, Springer, Cham, 103-111

Guo Y., Yin S., Ren Y., Zhu J., Yang S., Ye S., 2015, A multilevel calibration technique for an industrial robot with parallelogram mechanism. Precision Engineering, 40, 261-272

Hadavand M., Mirbagheri A., Behzadipour S., Farahmand F., 2014, A novel remote center of motion mechanism for the force‐reflective master robot of haptic tele‐surgery systems. The International Journal of Medical Robotics and Computer Assisted Surgery, 10(2), 129-139

Huang Z., Li Q.C., 2002, General methodology for type synthesis of symmetrical lower-mobility parallel manipulators and several novel manipulators. The International Journal of Robotics Research, 21(2), 131-145

Jaspers J.E., Breedveld P., Herder J.L., Grimbergen C.A., 2004, Camera and instrument holders and their clinical value in minimally invasive surgery. Surgical Laparoscopy Endoscopy & Percutaneous Techniques, 14(3), 145-152

Kim J.Y., 2006, Task based kinematic design of a two DOF manipulator with a parallelogram five-bar link mechanism. Mechatronics, 16(6), 323-329

Kong M.X., You W., Du Z.J., Sun L.N., 2010, Optimal design for a 2-DOF high dynamic manipulator based on parallelogram mechanism. In Advanced Intelligent Mechatronics (AIM), 2010 IEEE/ASME International Conference on, 242-247

Koseki Y., Koyachi N., Arai T., Chinzei K., 2003, Remote actuation mechanism for MR-compatible manipulator using leverage and parallelogram-workspace analysis, workspace control, and stiffness evaluation. In Robotics and Automation, 2003. Proceedings. ICRA'03. IEEE International Conference on, Vol. 1, 652-657

Kuo C.H., Dai J.S., 2009, Robotics for minimally invasive surgery: a historical review from the perspective of kinematics. In International symposium on history of machines and mechanisms. Springer, Dordrecht, 337-354

Kuo C.H., Dai J.S., Dasgupta P., 2012, Kinematic design considerations for minimally invasive surgical robots: an overview. The International Journal of Medical Robotics and Computer Assisted Surgery, 8(2), 127-145

Lee H., Cheon B., Hwang M., Kang D., Kwon D.S., 2018, A master manipulator with a remote‐center‐of‐motion kinematic structure for a minimally invasive robotic surgical system. The International Journal of Medical Robotics and Computer Assisted Surgery, 14(1), 12

Li G.K., Essomba T., Wu C.T., Lee S.T., Kuo C.H., 2017, Kinematic design and optimization of a novel dual-orthogonal remote center-of-motion mechanism for craniotomy. Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science, 231(6), 1129-1145

Liu X.J., Wang J., 2003, Some new parallel mechanisms containing the planar four-bar parallelogram. The International Journal of Robotics Research, 22(9), 717-732

Loser M.H., Navab N., 2000, A new robotic system for visually controlled percutaneous interventions under CT fluoroscopy. In International Conference on Medical Image Computing and Computer-Assisted Intervention . Springer, Berlin, Heidelberg, 887-896

Nawrat Z., Lis K., Lehrich K., Rohr K., Furjesb P., Ducso C., 2016, Control of Robin Heart Pelican robot with using a force feedback (in Polish). Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna, 22(3), 146-153

Pan B., Fu Y., Niu G., Xu D., 2014, Optimization and design of remote center motion mechanism of Minimally Invasive Surgical robotics. In Ubiquitous Robots and Ambient Intelligence (URAI), 2014 11th International Conference on, 3-6

Roh S.G., Lee Y., Lee J., Ha T., Sang T., Moon K.W., Choi J.Y., 2015, Development of the SAIT single-port surgical access robot slave arm based on RCM Mechanism. In Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE, 5285-5290

Rosen J., Brown J.D., Chang L., Barreca M., Sinanan M., Hannaford B., 2002, The BlueDRAGON-a system for measuring the kinematics and dynamics of minimally invasive surgical tools in-vivo. In Robotics and Automation, 2002. Proceedings. ICRA'02. IEEE International Conference on, Vol. 2, 1876-1881

Taylor R.H., Funda J., Eldridge B., Gomory S., Gruben K., LaRose D., Anderson J., 1995, A telerobotic assistant for laparoscopic surgery. IEEE Engineering in Medicine and Biology Magazine, 14(3), 279-288

Taylor R.H., Menciassi A., Fichtinger G., Fiorini P., Dario P., 2016, Medical robotics and computer-integrated surgery. In Springer handbook of robotics, Springer, Cham, 1657-1684

Trochimczuk R., 2017, Analysis of Parallelogram Mechanism used to Preserve Remote Center of Motion for Surgical Telemanipulator. International Journal of Applied Mechanics and Engineering, 22(1), 229-240

Trochimczuk R., 2013, Conception of arm of medical robot dedicated to application of minimally invasive surgery. In Solid State Phenomena, Vol. 198, Trans Tech Publications, Zurich, 3-8

Valdez S.I., Chávez-Conde E., Hernandez E.E., Ceccarelli M., 2016, Structure-control design of a mechatronic system with parallelogram mechanism using an estimation of distribution algorithm. Mechanics Based Design of Structures and Machines, 44(1-2), 58-71

Wang W., Li J., Wang S., Su H., Jiang X., 2016, System design and animal experiment study of a novel minimally invasive surgical robot. The International Journal of Medical Robotics and Computer Assisted Surgery, 12(1), 73-84

Yang Y., Jiang S., Yang Z., Yuan W., Dou H., Wang W., Bian Y., 2017, Design and analysis of a tendon-based computed tomography–compatible robot with remote center of motion for lung biopsy. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 231(4), 286-298

Yip H.M., Li P., Navarro-Alarcon D., Wang Z., Liu Y.H., 2014, A new circular-guided remote center of motion mechanism for assistive surgical robots. In Robotics and Biomimetics (ROBIO), 2014 IEEE International Conference on, 217-222

Yip H.M., Wang Z., Navarro-Alarcon D., Li P., Liu Y.H., Cheung T.H., 2015, A new robotic uterine positioner for laparoscopic hysterectomy with passive safety mechanisms: Design and experiments. In Intelligent Robots and Systems (IROS), 2015 IEEE/RSJ International Conference on, 3188-3194

Zhang Z., Yu H., Du Z., 2015, Design and kinematic analysis of a parallel robot with Remote Center of Motion for Minimally Invasive Surgery. In Mechatronics and Automation (ICMA), 2015 IEEE International Conference on, 698-703

Zong G., Pei X., Yu J., Bi S., 2008, Classification and type synthesis of 1-DOF remote center of motion mechanisms. Mechanism and Machine Theory, 43(12), 1585-1595