Journal of Theoretical
and Applied Mechanics

55, 1, pp. 369-376, Warsaw 2017
DOI: 10.15632/jtam-pl.55.1.369

Anatomical protocol for gait analysis: joint kinematics measurement and its repeatability

Magdalena Żuk, Marta Trzeciak
International Society of Biomechanics has proposed a general reporting standard for joint
kinematics based on anatomical reference frames. Nevertheless, the gait analysis protocols
based on this standard are still poorly reported. The purpose of the current study is to propose
and preliminarily assess the potential of an anatomically based ISB 6-DOF protocol,
which combines the ISB reporting standard together with a marker cluster technique. The
proposed technical marker set enables full description of the lower limb kinematics (including
three-dimensional ankle-foot complex rotations) according to the current biomechanical recommendation.
The marker set provides a clinically acceptable inter-trial repeatability and minimal equipment requirements.
Keywords: joint kinematics, gait analysis protocol, repeatability, anatomical protocol, marker-set, motion capture system